A Welder Performance Qualification Record (WPQR) documents that a specific welder has passed a qualification test under controlled conditions. It confirms the welder can execute welds in accordance with the requirements of a given Welding Procedure Specification. The WPQR belongs to the individual welder, not to the procedure.

Where a Procedure Qualification Record (PQR) validates the welding procedure itself, the WPQR validates the person carrying it out. Both documents are required for full compliance on most regulated projects. You cannot document weld quality if the people making the welds have not been formally qualified and recorded.

What a WPQR documents

A WPQR records everything relevant to a specific qualification test. This includes the welder’s identity, the test piece configuration (base material, dimensions, joint design), the welding process and consumables used, the test conditions, and the results of all required examinations. Visual inspection is mandatory. Destructive testing, radiographic examination, or bend tests are required depending on the applicable standard.

The record also specifies the qualified ranges that result from the test. These determine which production welds the welder is authorised to make. Ranges cover process, material group, dimension, and welding position. A qualification test in one combination does not automatically cover all variations.

Standards that govern WPQR requirements

The applicable standard depends on the project and industry. ISO 9606-1 applies to fusion welding of steels and is the primary standard used across European fabrication and construction. ISO 9606-2 covers aluminium and aluminium alloys. ASME Section IX is required on pressure equipment projects following American codes, particularly in the oil and gas and power sectors. AWS D1.1 governs structural steel welding in North American markets.

Each standard defines test conditions, acceptance criteria, qualified ranges, and validity requirements. If your projects require compliance with multiple standards, the qualification scope must be planned accordingly. A qualification valid under one standard is not automatically transferable.

Validity and the continuity requirement

Under ISO 9606-1, a welder’s qualification is valid for three years from the date of the test, provided continuity is confirmed at regular intervals. The responsible welding coordinator must verify every six months that the welder has been actively welding within the qualified range. This confirmation must be documented. If the six-month confirmation lapses, the qualification is no longer valid and requalification testing is required.

After three years, the qualification must either be renewed through a new test or prolonged based on satisfactory radiographic or ultrasonic examination results, depending on the requirements of the certifying body. Tracking these dates across a workforce of multiple welders is one of the most common documentation challenges in practice.

How qualification ranges determine production scope

A qualification test qualifies the welder for a defined set of production conditions, not for all welding. The ranges cover welding process, material group, material thickness, pipe diameter (where relevant), and welding position. Qualifying in flat position (PA) does not qualify the welder for overhead (PE) or vertical-up (PF) welds.

Planning the scope of qualification tests to cover the actual production range avoids both unnecessary retesting and gaps that emerge during audits. This planning should happen before welders are sent to testing, based on the WPSs that will be used in production. See how SOCWeld connects WPSs and welder qualifications in a single workflow.

Frequently asked questions

What is the difference between a WPQR and a PQR?

A PQR (Procedure Qualification Record) documents the outcome of a test weld made to qualify a welding procedure. It validates the procedure, not the welder. A WPQR documents a specific welder’s ability to execute welds in accordance with a WPS. The PQR supports the procedure; the WPQR supports the person.

How long is a WPQR valid under ISO 9606-1?

Three years, provided the welder’s continuity is confirmed every six months by the responsible welding coordinator. Without documented six-month confirmation, the qualification lapses regardless of how recently the welder has been working.

Who is responsible for issuing and maintaining WPQR documents?

The qualification test is typically witnessed and certified by an examining body or third-party inspector. The employer (fabricator) holds and maintains the WPQR records. The responsible welding coordinator is accountable for ensuring continuity confirmations are documented at the required intervals.

Can a single qualification test cover multiple positions?

Some test positions qualify the welder for additional positions. Under ISO 9606-1, for example, a PC (horizontal) test on plate qualifies for PA (flat) as well. The qualified ranges are defined in the standard’s tables and must be read carefully to avoid over- or under-scoping the test programme.

What happens if a welder’s continuity is not confirmed on time?

The qualification lapses. The welder is no longer formally qualified to make production welds within that scope until a new qualification test has been completed and documented. This can create production delays if it is not caught in advance. Automated reminders and scheduled reviews are the practical solution.